B&L Cremation Phoenix II-3 Human Crematory

The B&L Cremation Systems, Inc. Phoenix II-3 human crematory is our high volume, hot-load production system, with average cremation times of 45 to 60 minutes.  It has a 1,000 pound load capacity.

CONTROL SYSTEM AND POLLUTION MONITORING – This system constantly monitors the stack gases to prevent visible emissions.  Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.

FULLY-AUTOMATIC CONTROL SEQUENCE – Operation is made simple by the fully-automatic control sequence.  A microprocessor temperature controller with a digital readout ensures optimum control while providing the lowest fuel consumption.  Visual verification of each stage is provided on the control panel.  Operator override is achieved by a turn of a switch for semi-manual control.

HOT HEARTH DESIGN – First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption, and extending the hearth life.

HYDRAULIC LOADING DOOR – Push-button operated, this feature enables the operator to open the door to the desired height from the control panel.  An important safety feature for busy installations, it provides better fuel efficiency and longer refractory life.

LOW NOISE – The secondary combustion blower has been manufactured and installed to allow for low noise operation.

MULTI-CHAMBER AIR CONTROLLED DESIGN – The entire combustion process is completed within the air controlled chambers, allowing for 24 hour operation, eliminating burning in the stack, and providing for greater fuel efficiency over excess air designs.

REFRACTORY – Our exclusive features are high-duty refractory walls in all chambers and six inch, 3,000 degree Farenheit high-duty bricks in all non-insulating areas.  The hearth is cast from 3,000 degree Farenheit abrasive resistant material, and the main chamber ceiling is insulating firebrick to provide better fuel efficiency and longevity.

REFRACTORY LINED STACK – A three inch insulating liner is provided as a safety feature.  While gases seldom exceed 1,000 degrees Farenheit, the liner reduces heat penetration under every condition, preventing the possibility of fire.  A ten year warranty is offered on the stack liner.

REMAINS REMOVAL SYSTEM – A separate remains removal door, located on the side of the unit, is included to enable the operator to push the remains to the rear of the chamber, reducing heat loss and thermal shock as the loading door needs only to be opened six to eight inches for removal.  A stainless steel cooling pan is located on the outside of the unit to prevent fluid contamination.

STAINLESS STEEL FRONT – More than just aesthetics.  Stainless steel is easy to clean, while also providing a professional finish to your equipment…an important feature when considering a viewing.

STARTUP – Startup is made easy, as our units are fully piped, tested, and wired prior to shipment from the factory.  Once the machine has been off-loaded and the stack and utilities hooked up, our factory-trained crematory technicians are available for startup and training service for up to five people.

TOUCHSCREEN CONTROLS – Our ten inch touchscreen operating system completely controls the cremation process, making less room for user error.  Our system also allows you to log in with a username and password before you operate the machine.  You may then enter the I.D., name, and weight of the deceased while our storage and retrieval system allows you to keep track of every cremation done.  An ethernet cable port, located on the inside door of the control panel, allows you to plug into the Internet and have our crematory technicians troubleshoot any problems you may have right from our facility, no matter where you are in the world.

Length: 13′ – 2″
Width: 8′ – 6″
Height: 8′ – 0″ (9′ – 6″ with Doorcap)
Weight: 42,000 lbs
Door
Opening:
3′ – 9″ Width x 2′ – 8″ Height
Rear Door
Opening:
3′ – 9″ Width x 1′ – 0″ Height
Gas
Pressure:
Natural Gas: 7″ W.C.
Propane Gas: 11″ W.C.
Power
Requirements:
220 V, Single Phase, 45 AMPS
(Available in 3 Phases and 50 Cycle Options)
110 V, Single Phase, 10 AMPS
Body Weight
Capability:
1,000 lbs
Cremation
Rate:
250 lbs/hr
Stack Height
From Grade:
Minimum 18′
Stack
Sections:
30″ O.D.
Chamber
Dimensions:

Length: 140″
Width: 52″
Height: 36″

Burner
Output:
Afterburner Maximum: 1,000,000 BTU per Hour
Cremation Burner: 500,000 BTU per Hour
Emission Burner: 200,000 BTU per Hour
Ignition Burner: 300,000 BTU per Hour
Maximum Input Rating: 1,700,000 BTU per Hour
Modulation Minimum: 100,000 BTU per Hour
Air
Requirements:
Outside air inlet louvers in the room located
at or below burner height, capable of passing
2,500 ft³ per minute of free air.
Length: 3.25 m
Width: 2.57 m
Height: 2.44 m (2.90 m with Doorcap)
Weight: 15,875.73 kg
Door
Opening:
1.14 m Width x 0.81 m Height
Rear Door
Opening:
1.14 m Width x 0.30 m Height
Gas
Pressure:
Natural Gas: 1.74 kPa W.C.
Propane Gas: 2.74 kPa W.C.
Power
Requirements:
220 V, Single Phase, 45 AMPS
(Available in 3 Phases and 50 Cycle Options)
110 V, Single Phase, 10 AMPS
Body Weight
Capability:
453.59 kg
Cremation
Rate:
113.40 kg/hr
Stack Height
From Grade:
5.49 m
Stack
Sections:
76.20 cm O.D.
Chamber
Dimensions:
Length: 304.80 cm
Width: 114.30 cm
Height: 86.36 cm
3.01 m³
Burner
Output:
Afterburner Maximum: 1,055,055.85 kJ per Hour
Cremation Burner: 527,527.93 kJ per Hour
Emission Burner: 211,011.17 kJ per Hour
Ignition Burner: 316,516.76 kJ per Hour
Maximum Input Rating: 1,793,594.95 kJ per Hour
Modulation Minimum: 105,505.59 kJ per Hour
Air
Requirements:
Outside air inlet louvers in the room located
at or below burner height, capable of passing
70.79 m³ per minute of free air.

    N-20SA Human Crematory

    The B&L Cremation Systems, Inc. N-20SA human crematory is our low volume production system, with average cremation times of 150 minutes.

    N-20AA Human Crematory

    The B&L Cremation Systems, Inc. N-20AA human crematory is our medium volume production system, with average cremation times of 100 to 120 minutes.

    N-20 Human Crematory

    The B&L Cremation Systems, Inc. N-20 human crematory is our low to medium volume production system, with average cremation times of 120 minutes.

    Phoenix II-1 Human Crematory

    The B&L Cremation Systems, Inc. Phoenix II-1 Human Crematory is our medium volume production system, with average cremation times of 70 to 90 minutes.  It has a 1,000 pound load capacity.

    Phoenix II-2 Human Crematory

    The B&L Cremation Systems, Inc. Phoenix II-2 human crematory is our medium to high volume production system, with average cremation times of 60 to 70 minutes.  It has a 1,000 pound load capacity.

    BLI 400 MW Incinerator

    The B&L Cremation Systems, Inc. BLI 400 MW medical/pathological waste incinerator is our smallest system.  It has a primary chamber volume of 23 cubic feet, and an afterburner rating of 75 pounds per hour.

    BLI 800 MW Incinerator

    The B&L Cremation Systems, Inc. BLI 800 MW medical/pathological waste incinerator has a primary chamber volume of 54 cubic feet.  The burn rate is 100 pounds per hour.

    BLI 1500 MW Incinerator

    The B&L Cremation Systems, Inc. BLI 1500 MW medical/pathological waste incinerator is a batch load system.  It has a primary chamber volume of 110 cubic feet and is rated at 200 pounds per hour.

    BLI 2500 MW Incinerator

    Our largest batch load system, the B&L Cremation Systems, Inc. BLI 2500 MW medical/pathological waste incinerator, has a primary chamber volume of 170 cubic feet and a burn rating of 250 pounds per hour.

    BLI 5000 MW Incinerator

    The B&L Cremation Systems, Inc. BLI 5000 MW medical/pathological waste incinerator is a continuous feed style system with an operational rate of 350 pounds per hour.