B&L Cremation BLI 400 MW Incinerator
The B&L Cremation Systems, Inc. BLI 400 MW medical/pathological waste incinerator is our smallest system. It has a primary chamber volume of 23 cubic feet, and an afterburner rating of 75 pounds per hour.
Further information on fuel, oil, and specifications will be given upon request.
FULLY AUTOMATIC CONTROL SEQUENCE – Operation is made simple by the fully automatic control sequence. A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption. Visual verification of each stage is provided on the control panel. Operator override is achieved by a turn of a switch for semi-manual control.
MULTI-CHAMBER AIR CONTROLLED DESIGN – The entire combustion process is completed within the air controlled chambers, eliminating burning in the stack, allowing for 24 hour operation, and providing for greater fuel efficiency over excess air designs.
POLLUTION MONITORING & CONTROL SYSTEM – This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.
REFRACTORY LINED STACK – A three inch insulating liner is provided as a safety feature. While gases seldom exceed 1,000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire. A ten year warranty is offered on the stack liner.
LOW NOISE – The secondary combustion blower has been manufactured and installed to allow for low noise operation.
Length: | 125″ (133″ with cremation burner) |
Width: | 64″ (78″ with control panel) |
Height: | 72″ (84″ with afterburner) |
Weight: | 19,000 lb |
Gas Pressure: |
Natural Gas: 7″ W.C. Propane Gas: 11″ W.C. |
Power Requirements: |
220 V, single phase, 30 AMPS |
Incineration Rate: |
75 lb/hr |
Body Weight Capability: |
800 lb |
Stack Height From Grade: |
minimum 15′ |
Stack Sections: |
24″ O.D. |
Refractory/ Insulation: |
4.50″ firebrick walls castable refractory lining (hearth and ceiling) 3″ 1900 – board insulation |
Chamber Dimensions: |
Length: 65″ Width: 40″ Height: 36″ 54 ft³ |
Burner Output: |
Maximum Input Rating: 1,800,000 BTU’s per hour Afterburner Maximum: 1,000,000 BTU’s per hour Modulation Minimum: 100,000 BTU’s per hour Cremation Burner: 800,000 BTU’s per hour |
Air Requirements: |
Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 ft³ per minute of free air. |
Length: | 3.18 m (3.38 m with cremation burner) |
Width: | 1.63 m (1.98 m with control panel) |
Height: | 1.83 m (2.13 m with afterburner) |
Weight: | 8,618.26 Kg |
Gas Pressure: |
Natural Gas: 1.74 kPa W.C. Propane Gas: 2.74 kPa W.C. |
Power Requirements: |
220 V, single phase, 30 AMPS |
Incineration Rate: |
34.02 Kg/hr |
Body Weight Capability: |
362.87 Kg |
Stack Height From Grade: |
4.57 m |
Stack Sections: |
609.60 mm O.D. |
Refractory/ Insulation: |
0.11 m firebrick walls castable refractory lining (hearth and ceiling) 0.08 m 1900 – board insulation |
Chamber Dimensions: |
Length: 1.65 m Width: 1.02 m Height: 0.91 m 1.53 m³ |
Burner Output: |
Maximum Input Rating: 1,899,100.08 KJ per hour Afterburner Maximum: 1,055,055.60 KJ per hour Modulation Minimum: 105,505.56 KJ per hour Cremation Burner: 844,044.48 KJ per hour |
Air Requirements: |
Outside air inlet louvers in the room located at or below burner height, capable of passing 1.18 m³ per second of free air. |