B&L Cremation BLP 1000 Animal Crematory
The B&L Cremation Systems, Inc. BLP 1000 animal crematory is designed for large veterinarian facilities. It is used for individual cremation or a maximum load size of 1,000 lbs.
FULLY AUTOMATIC CONTROL SEQUENCE – Operation is made simple by the fully automatic control sequence. A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption. Visual verification of each stage is provided on the control panel. Operator override is achieved by a turn of a switch for semi-manual control
HOT HEARTH DESIGN – First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption, and extending the hearth life.
MULTI-CHAMBER AIR CONTROLLED DESIGN – The entire combustion process is completed within the air controlled chambers, eliminating burning in the stack, allowing for 24 hour operation, and providing for greater fuel efficiency over excess air designs.
POLLUTION MONITORING & CONTROL SYSTEM – This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.
REFRACTORY LINED STACK – A three inch insulating liner is provided as a safety feature. While gases seldom exceed 1,000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire. A ten year warranty is offered on the stack liner.
LOW NOISE – The secondary combustion blower has been manufactured and installed to allow for low noise operation.
Length: | 150″ |
Width: | 70″ (80″ with control panel) |
Height: | 110″ (114″ with doorcap) |
Weight: | 32,000 lb |
Door Opening: |
46″ width x 32″ height |
Gas Pressure: |
Natural Gas: 7″ W.C. Propane Gas: 11″ W.C. |
Power Requirements: |
220 V, single phase, 60 cycle, 30 AMPS & 110 V, single phase, 60 cycle, 10 AMPS |
Body Weight Capability: |
1,000 lb |
Cremation Rate: |
250 lb/hr |
Stack Height From Grade: |
minimum 18′ |
Stack Sections: |
26″ O.D. |
Chamber Dimensions: |
Length: 86″ Width: 46″ Height: 38″ 86.90 ft³ |
Burner Output: |
Maximum Input Rating: 2,250,000 BTU’s per hour Afterburner Maximum: 1,000,000 BTU’s per hour Modulation Minimum: 100,000 BTU’s per hour Cremation Burner: 750,000 BTU’s per hour |
Air Requirements: |
Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 ft³ per minute of free air. |
Length: | 3.81 m |
Width: | 1.78 m (2.03 m with control panel) |
Height: | 2.79 m (2.90 m with doorcap) |
Weight: | 14,514.96 Kg |
Door Opening: |
1,168.40 mm width x 812.80 mm height |
Gas Pressure: |
Natural Gas: 1.74 kPa W.C. Propane Gas: 2.74 kPa W.C. |
Power Requirements: |
220 V, single phase, 60 cycle, 30 AMPS & 110 V, single phase, 60 cycle, 10 AMPS |
Body Weight Capability: |
453.59 Kg |
Cremation Rate: |
113.40 Kg/hr |
Stack Height From Grade: |
5.49 m |
Stack Sections: |
660.40 mm O.D. |
Chamber Dimensions: |
Length: 2.18 m Width: 1.17 m Height: 0.97 m 2.46 m³ |
Burner Output: |
Maximum Input Rating: 2,373,875.10 KJ per hour Afterburner Maximum: 1,055,055.60 KJ per hour Modulation Minimum: 105,505.56 KJ per hour Cremation Burner: 791,291.70 KJ per hour |
Air Requirements: |
Outside air inlet louvers in the room located at or below burner height, capable of passing 1.18 m³ per second of free air. |