Specification U.S. Standard Metric System
Length: 7′ – 11″ 2.41 m
Width: 5′ – 2″ (6′ – 1″ with Control Panel) 1.57 m (1.85 m with Control Panel)
Height: 7′ – 6″ (8′ – 0″ with Doorcap) 2.29 m (2.44 m with Doorcap)
Weight: 15,000 lbs 6,803.89 kg
Door Opening: 3′ – 2″ Width x 2′ – 2″ Height 0.97 m Width x 0.66 m Height
Gas Pressure: Natural Gas: 7″ W.C.
Propane Gas: 11″ W.C.
Natural Gas: 1.74 kPa W.C.
Propane Gas: 2.74 kPa W.C.
Power Requirements: 220 V, Single Phase, 30 AMPS
110 V, Single Phase, 10 AMPS
Body Weight Capability: 200 lbs 90.72 kg
Cremation Rate: 75 lbs/hr 34.02 kg/hr
Stack Height From Grade: Minimum 17.60′ 5.36 m
Stack Sections: 18″ O.D. 45.72 cm O.D.
Chamber Dimensions: Length: 50″
Width: 38″
Height: 32″
35 ft³
Length: 127 cm
Width: 96.52 cm
Height: 81.28 cm
0.99 m³
Burner Output: Afterburner Maximum: 800,000 BTU per Hour
Cremation Burner: 300,000 BTU per Hour
Maximum Input Rating: 1,100,000 BTU per Hour
Modulation Minimum: 100,000 BTU per Hour
Afterburner Maximum: 844,044.68 kJ per Hour
Cremation Burner: 316,516.76 kJ per Hour
Maximum Input Rating: 1,160,561.44 kJ per Hour
Modulation Minimum: 105,505.59 kJ per Hour
Air Requirements: Outside air inlet louvers in the room located
at or below burner height, capable of passing
2,500 ft³ per minute of free air.
Outside air inlet louvers in the room located
at or below burner height, capable of passing
70.79 m³ per minute of free air.

Features Of The BLP 200 Animal Crematory


CONTROL SYSTEM AND POLLUTION MONITORING – This system constantly monitors the stack gases to prevent visible emissions.  Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.

FULLY-AUTOMATIC CONTROL SEQUENCE – Operation is made simple by the fully-automatic control sequence.  A microprocessor temperature controller with a digital readout ensures optimum control while providing the lowest fuel consumption.  Visual verification of each stage is provided on the control panel.  Operator override is achieved by a turn of a switch for semi-manual control.

HOT HEARTH DESIGN – First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption, and extending the hearth life.

LOW NOISE – The secondary combustion blower has been manufactured and installed to allow for low noise operation.

MULTI-CHAMBER AIR CONTROLLED DESIGN – The entire combustion process is completed within the air controlled chambers, allowing for 24 hour operation, eliminating burning in the stack, and providing for greater fuel efficiency over excess air designs.

REFRACTORY LINED STACK – A three inch insulating liner is provided as a safety feature.  While gases seldom exceed 1,000 degrees Farenheit, the liner reduces heat penetration under every condition, preventing the possibility of fire.  A ten year warranty is offered on the stack liner.

Back to BLP 200 M3 Animal Crematory Next BLP 100 Animal Crematory