The B&L Cremation Systems, Inc. Phoenix II-2 human crematory is our medium to high volume production system, with average cremation times of 60 to 70 minutes.  It has a 1,000 pound load capacity.

Download Installation Manual

Specification U.S. Standard Metric System
Length: 10′ – 8″ 3.25 m
Width: 8′ – 5″ 2.57 m
Height: 8′ – 0″ (9′ – 6″ with Doorcap) 2.44 m (2.90 m with Doorcap)
Weight: 35,000 lbs 15,875.73 kg
Door Opening: 3′ – 9″ Width x 2′ – 8″ Height 1.14 m Width x 0.81 m Height
Rear Door Opening: 3′ – 9″ Width x 1′ – 0″ Height 1.14 m Width x 0.30 m Height
Gas Pressure: Natural Gas: 7″ W.C.
Propane Gas: 11″ W.C.
Natural Gas: 1.74 kPa W.C.
Propane Gas: 2.74 kPa W.C.
Power Requirements: 220 V, Single Phase, 45 AMPS
(Available in 3 Phases and 50 Cycle Options)
110 V, Single Phase, 10 AMPS
Body Weight Capability: 1,000 lbs 453.59 kg
Cremation Rate: 150 lbs/hr 68.04 kg/hr
Stack Height From Grade: Minimum 18′  5.49 m
Stack Sections:  30″ O.D. 76.20 cm O.D.
Chamber Dimensions: Length: 104″
Width: 46″
Height: 34″
92 ft³
Length: 264.16 cm
Width: 116.84 cm
Height: 86.36 cm
2.61 m³
Burner Output: Afterburner Maximum: 1,000,000 BTU per Hour
Cremation Burner: 500,000 BTU per Hour
Emission Burner: 200,000 BTU per Hour
Ignition Burner: 300,000 BTU per Hour
Maximum Input Rating: 1,500,000 BTU per Hour
Modulation Minimum: 100,000 BTU per Hour
Afterburner Maximum: 1,055,055.85 kJ per Hour
Cremation Burner: 527,527.93 kJ per Hour
Emission Burner: 211,011.17 kJ per Hour
Ignition Burner: 316,516.76 kJ per Hour
Maximum Input Rating: 1,582,583.78 kJ per Hour
Modulation Minimum: 105,505.59 kJ per Hour
Air Requirements: Outside air inlet louvers in the room located
at or below burner height, capable of passing
2,500 ft³ per minute of free air.
Outside air inlet louvers in the room located
at or below burner height, capable of passing
70.79 m³ per minute of free air.