The B&L Cremation Systems, Inc. Phoenix II-1 Human Crematory is our medium volume production system, with average cremation times of 70 to 90 minutes.  It has a 1,000 pound load capacity.

Download Installation Manual

Specification U.S. Standard Metric System
Length: 13′ – 0″ 3.96 m
Width: 6′ – 0″ (6′ – 11″ with Control Panel) 1.83 m (2.13 m with Control Panel)
Height: 8′ – 0″ (8′ – 9″ with Doorcap) 2.44 m (2.64 m with Doorcap)
Weight: 32,000 lbs 14,514.96 kg
Clean Out Door Opening: 1′ – 9.75″ Width x 1′ – 7.75″ Height 0.55 m Width x 0.50 m Height
Door Opening: 3′ – 10″ Width x 2′ – 8″ Height 1.17 m Width x 0.81 m Height
Gas Pressure: Natural Gas: 7″ W.C.
Propane Gas: 11″ W.C.
Natural Gas: 1.74 kPa W.C.
Propane Gas: 2.74 kPa W.C.
Power RQMTS:
  • 220 V, Single Phase, 45 AMPS (Available in 3 Phases and 50 Cycle Options)
  • 110 V, Single Phase, 10 AMPS
Body Weight Capability: 1,000 lbs 453.59 kg
Cremation Rate: 150 lbs/hr 68.04 kg/hr
Stack Height From Grade: Minimum 18′ 5.49 m
Stack Sections: 30″ O.D. 76.20 cm O.D.
Chamber Dimensions: Length: 100″
Width: 45″
Height: 36.5″
97.10 ft³
Length: 254 cm
Width: 114.30 cm
Height: 92.71 cm
2.75 m³
Burner Output:
  • Afterburner Maximum: 1,000,000 BTU per Hour
  • Cremation Burner: 500,000 BTU per Hour
  • Ignition Burner: 300,000 BTU per Hour
  • Maximum Input Rating: 1,500,000 BTU per Hour
  • Modulation Minimum: 100,000 BTU per Hour
  • Afterburner Maximum: 1,055,055.85 kJ per Hour
  • Cremation Burner: 527,527.93 kJ per Hour
  • Ignition Burner: 316,516.76 kJ per Hour
  • Maximum Input Rating: 1,582,583.78 kJ per Hour
  • Modulation Minimum: 105,505.59 kJ per Hour
Air RQMTS: Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 ft³ per minute of free air. Outside air inlet louvers in the room located at or below burner height, capable of passing 70.79 m³ per minute of free air.